Rimnac, C. M.(2014).What Design and Material Factors Impact the Wear and Corrosion Performance in Total Elbow Arthroplasties? (vol 472, pg 3770, 2014).,472(10),3245-3245.
Advincula, R. C., & Park, J. C.(2014).Tunable Electroluminescent Properties in CdSe/PVK Guest-Host Based Light-Emitting Devices.PCCP- Physical Chemiistry Chemical Physics,16, 8589.
Ishida, H., & Ishida, H.(2014).Anomalous Isomer Effect on the Properties of Bisphenol F-based Benzoxazines: Towards the Molecular Design for Higher Performance.Macromolecules,47, 5682-5690.
Miller, M., Goodheart, J., Izant, T., Rimnac, C. M., Cleary, R. M., & Tillmann, K. M.(2014).Loss of cement-bone interlock in retrieved tibial components from total knee arthroplasties..Clinical orthopaedics and related research,472(1),304-13.
Ishida, H., Lacks, D. J., Ishida, H. J., & Qutubuddine, S. J.(2014).Molecular Dynamics Simulation of the Amphiphilic, Comb-like Anionic Polybenzoxazines.Langmuir,30, 11858-11865.
Baer, E., Offord, G., Armstrong, S., Freeman, B., Paul, D., & Hiltner, A.(2014).Gas Transport in Co-extruded Multilayered Membranes with Alternating Dense and Porous Polymeric Layers.POLYMER,55, 1259.
Ishida, H., Froimowicz, P., Landfester, K., Taden, A., & Ishida, H.(2014).Triggered Precision Benzoxazine Film Formation by Thermally Induced Destabilization of Benzoxazine Nano-Droplets Using a LCST-bearing Surfactant.Macromolecules,47, 3297-3305.
Khani, S., & Maia, J. M.(2014).High strain extensional rheometry of polymer melts: revisiting and improving the Meissner design..Journal of Rheology,58, 869-890.
Maia, J. M.(2014).The Influence of Thermo-Mechanical History on Structure Development of Elastomeric and Amorphous Glass Thermoplastic Polyurethanes.Polymer Engineering and Science,54, 1383-1393.
Sobieraj, M., Murphy, J., Brinkman, J., Kurtz, S., & Rimnac, C. M.(2013).Monotonic and fatigue behavior of five clinically relevant conventional and highly crosslinked UHMWPEs in the presence of stress concentrations..Journal of the mechanical behavior of biomedical materials,28, 244-53.
Alhassan, S., Qutubuddin, S., Schiraldi, D. A., Agag, T. A., & Ishida, H. A.(2013).Preparation and thermal properties of graphene oxide/main chainbenzoxazine polymer.EUROPEAN POLYMER JOURNAL,49(12),3825-3833.
Herbert, M., Andrade, R., Ishida, H., Maia, J. M., & Schiraldi, D. A.(2013).Multilayered confinement of iPP/TPOSS and nylon 6/APOSS blends.POLYMER,54(26),6992-7003.
Alhassan, S., Qutubuddin, S., Schiraldi, D. A., Agag, T. A., & Ishida, H. A.(2013).Preparation and thermal properties of graphene oxide/main chain
benzoxazine polymer.EUROPEAN POLYMER JOURNAL,49(12),3825-3833.
Kurtz, S., Kocagoz, S., Hanzlik, J., Underwood, R., Gilbertson, J., MacDonald, D., Lee, H., Mont, M., Kraay, M., Klein, G., Parvizi, J., & Rimnac, C. M.(2013).Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study..Clinical orthopaedics and related research,471(10),3270-82.
Dagnon, K., Way, A., Carson, S., Silva, J., Maia, J. M., & Rowan, S. J.(2013).Controlling the Rate of Water-Induced Switching in Mechanically DynamicCellulose Nanocrystal Composites.MACROMOLECULES,46(20),8203-8212.
Higgs, G., Hanzlik, J., MacDonald, D., Gilbertson, J., Rimnac, C. M., & Kurtz, S. M.(2013).Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study..The Journal of arthroplasty,28(8 Suppl),2-6.
Ishida, H.(2013).Dielectric Properties at Microwave Frequency in Barium Strontium Titanate/Poly(benzoxzine-urethane) Composite Films.Ferroelectrics,452, 84-90.
Wang, Y., Gawryla, M., & Schiraldi, D. A.(2013).Effects of freezing conditions on the morphology and mechanical
properties of clay and polymer/clay aerogels.JOURNAL OF APPLIED POLYMER SCIENCE,129(3),1637-1641.